Product Features:
- Fully automatic, random access.
- Stable flux 240 T / H.
- Frozen reagent section.
- 8-stop washing system 12 steps.
- LIS interface, support remote maintenance.
- Reagents and test samples in the same tray (user defined position respectively), total of 67 positions.
Model: CS-T240
Manufacturer: DIRUI
Country of Origin: China.
Technical data :
-
- Equipment overview
- Device type: Fully automatic, separate, with STAT mode.
- Analysis Speed: 240 Test / hour (single and double chemical).
- Measuring principle: Colorimetric method, turbidity measurement method.
- Analytical method:
- Endpoint, kinetics, fixed time ,…
- Support single / double wavelength and 1-2 sample multi reagent, linear and non-linear standard.
- Reagent and sample trays.
- Sample and reagent location :
- The reagent and sample are shared with 1 tray, total 67 positions.
- Samples and reagents are cooled at 5 – 150 ° C within 24 hours.
- Sample Cuvette: Standard cup, original blood tube, tube with many sizes (Ø12 ~ 16) mm × (25 ~ 100) mm.
- Sample volume: 3µl-35µl, 0.1µl step (step).
- Reagent volume: R1: 10µl- 350µl, R2: 10µl- 200µl, 0,1µl step (step).
- Sample and chemical probe: 1, has the function of detecting liquid level and clogging.
- Cross contamination rate on sample probe and reagent: Automatic washing with hot water. Cross-contamination rate ≤0.1%.
- Automatic sample dilution: 3 ~ 115
- Sample and reagent location :
- Reaction tray
- Reaction Cuvette: 120 positions for optical plastic cuvette, optical diameter 6mm
- The total volume of the reflux solution: 150µl-550µl
- Reaction temperature: 37˚C, ± 0.1˚C
- Stable temperature of reaction plate: Circulating water.
- Mixing needle: 1, mix immediately after aspirating the reagent.
- Clean reaction cuvet: With 8 stops, 12 steps with warm water.
- Wastewater treatment: Concentrated wastewater level warning function.
- Optical system
- Light source: 20W / 12V halogen lamp.
- Monochrome images: Optical illumination.
- Optical path: After spectroscopy measurement.
- Wavelengths: 340nm, 380nm, 405nm, 450nm, 480nm, 505 nm, 546 nm, 570 nm, 600 nm, 660nm, 700 nm, 750 nm, or 800 nm.
- Detection device: Photodiode LED array.
- OD linear range: 0 ~ 3.3 Abs.
- Standards and QC
- Standard method: 1 point linearity method, 2 point linearity method, multi point and non-linear.
- QC method: real-time QC, one-time QC and monthly QC.
- Out of control: Test piece alerted out of control, documented cause out of control.
- Operating system
- Computer requirements: Windows XP operating system.
- Software: Using graphic software, in English.
- Minimum configuration required: CPU ≥ 2.2GHz (dual-core processor), Memory ≥ 1G, Harddisk ≥ 160G, 17 inch LCD, laser printer, stylus, inkjet (optional).
- Connection: Connect to a computer via RS-232C port.
- Other information
- Dimensions: 998 mm x 752 mm x 517 mm
- Weight: 120 kg
- Power supply: 220V ± 22V, 50Hz / 60Hz, power consumption 650VA.
- Equipment overview