Automatic biochemical analyzer DIRUI CS-480

Model: CS-480
Manufacturer: Dirui
Origin: China

Price: Contact

Product Features:

  • Fully automatic, random access.
  • Flux.
    • 400 Test / h for biochemical analysis.
    • 800 test / h with ISE only (optional)
  • Analytical method
    • Endpoint, kinetics, fixed time etc.,
    • Support single / double wavelength.
  • Simultaneous analysis samples: 110 colorimetric samples and 3 ISE samples (optional k, Na, CL).

1. Equipment overview

  • Equipment type: Fully automatic, separate, with priority for STAT model
  • Flux :
    • 400 Test / h for biochemical analysis.
    • 800 test / h with ISE only (optional)
  • Measuring Principle: Colorimetry, turbidimetry, ISE
  • Analysis method:
    • Endpoint, kinetics, fixed time etc.,
    • Single / double wavelength
  • Simultaneous analysis samples: 110 colorimetric samples and 3 ISE samples (optional k, Na, CL)

2. Sample location

  • Sample position: 115 sample positions
  • Sample volume: 1.5µl ~ 35µl, 0.1µl stepping
  • Sample Cuvette: Standard cup, original (blood) sample tube, tubes with different sizes (Ø10 ~ 13) mm x (75 ~ 100) mm
  • Sample barcode: code 128, code 39, code 93, l2of5, UPC / EAN
  • Sampling technology: Detects liquid ink and resists.

3. Reagent location

  • Suction needle (probe): 1, with liquid level detection and shock resistance function
  • Reagent volume: 20µl-350µl, 1 µl stepping.
  • Reagent position: Dual reagent tray with up to 112 positions
  • Reagent barcode: code 128

4. Reaction location

  • Reaction cuvvet: 120 plastic optical cuvette hole positions
  • Total reaction volume: 120µl-450µl
  • Reaction temperature: 37˚C, ± 0.1˚C
  • Stable temperature of the reaction plate: Circulating water
  • Mixing needle: mix well after smoking reagent.
  • Reaction cuvvet washing: 7 washing stations with 11 steps, cleaned with warm water
  • Waste treatment :
    • There are two levels of flow with low and high concentration of wastewater.
    • There is a concentrated wastewater warning.

5. Optical system

  • Light source: Halogen lamp: 20W / 12V.
  • Monochromator: Grating photometry
  • Photoelectron road: Rear spectrophotometry
  • Wavelength: 340nm ~ 800nm.
  • Detector: Bipolar LED.
  • OD linear range: 0 ~ 3.6 Abs

6. Standards and QC.

  • Calibration method: 1-point, 2-point, multi-point, and zero-point linearity method.
  • QC method: real-time QC, one-by-one and monthly QC.
  • Handling samples out of control: The test piece is alerted when out of control, with the cause recorded.

7. Operating system

  • Operating System: Windows 7 / Windows 10
  • Analysis software: Using graphic software in English
  • Report Print: Report formats support QC mode viewer and status information, etc.
  • System connection: RJ45 network interface.

8. Other information

  • Dimensions: 1060 mm x 790 mm x 1150 mm.
  • Weight: 300 kg.
  • Power supply: Voltage 220V ± 22V, 50Hz ± 1Hz, power source 2000VA.